Hybrid Storage Management for Database Systems
Summary: Hybrid SSD/HDD storage for DBMS; introduces cost-aware replacement that jointly optimizes the DBMS buffer pool and SSD caching, and studies how policy choices shape SSD access patterns. Implemented in MySQL InnoDB; TPC-C evaluation shows cost-adjusted caching outperforms prior approaches. (summarized by gpt-5-nano on Feb 09 2026)
Incoming Non-self Citations Over Time
Authors
- 1. Xin Liu
- 2. Kenneth Salem
Incoming Citations (Sorted by Pagerank)
Showing 5 of 5 citing papers.
| Rank | Citing Paper | Year | Venue | Pagerank |
|---|---|---|---|---|
| 1,661 | Managing Non-Volatile Memory in Database Systems | 2018 | SIGMOD | 0.00010978755 |
| 2,824 | BlueCache: A Scalable Distributed Flash-based Key-value Store | 2017 | VLDB | 8.0589366e-05 |
| 3,905 | Native Store Extension for SAP HANA | 2019 | VLDB | 6.6408563e-05 |
| 7,061 | Serving Deep Learning Models with Deduplication from Relational Databases | 2022 | VLDB | 4.8463881e-05 |
| 8,631 | Parallel I/O Aware Query Optimization | 2014 | SIGMOD | 4.4806824e-05 |
Previous
Page 1 / 1
Next
Outgoing Citations (Sorted by Pagerank)
Showing 9 of 9 cited papers.
Citations counted here include only citations to other VLDB/SIGMOD/CIDR/PODS papers in this database.
| Rank | Cited Paper | Year | Venue | Pagerank |
|---|---|---|---|---|
| 1,060 | Flashing Up the Storage Layer | 2008 | VLDB | 0.00014370687 |
| 1,145 | FlashStore: High Throughput Persistent Key-Value Store | 2010 | VLDB | 0.00013685924 |
| 1,817 | SSD Bufferpool Extensions for Database Systems | 2010 | VLDB | 0.00010435936 |
| 3,354 | An Object Placement Advisor for DB2 Using Solid State Storage | 2009 | VLDB | 7.1837096e-05 |
| 3,365 | Turbocharging DBMS Buffer Pool Using SSDs | 2011 | SIGMOD | 7.1728897e-05 |
| 5,465 | Workload-Aware Storage Layout for Database Systems | 2010 | SIGMOD | 5.4919488e-05 |
| 5,724 | Flash-Based Extended Cache for Higher Throughput and Faster Recovery | 2012 | VLDB | 5.3518469e-05 |
| 6,043 | Operation-Aware Buffer Management in Flash-based Systems | 2011 | SIGMOD | 5.2386942e-05 |
| 7,247 | hStorage-DB: Heterogeneity-aware Data Management to Exploit the Full Capability of Hybrid Storage Systems | 2012 | VLDB | 4.790684e-05 |
Previous
Page 1 / 1
Next
Semantically Similar Papers
| Overall Rank | Paper | Year | Venue | Pagerank |
|---|---|---|---|---|
| 493 | A Case for Flash Memory SSD in Enterprise Database Applications | 2008 | SIGMOD | 0.00021837534 |
| 10,422 | ACE-in-Action: A Smart DBMS Bufferpool for SSDs | 2025 | SIGMOD | 4.1945683e-05 |
| 5,225 | Optimizing Databases by Learning Hidden Parameters of Solid State Drives | 2020 | VLDB | 5.6194324e-05 |
| 1,661 | Managing Non-Volatile Memory in Database Systems | 2018 | SIGMOD | 0.00010978755 |
| 1,700 | Bridging the Archipelago between Row-Stores and Column-Stores for Hybrid Workloads | 2016 | SIGMOD | 0.00010858865 |
| 3,354 | An Object Placement Advisor for DB2 Using Solid State Storage | 2009 | VLDB | 7.1837096e-05 |
| 5,403 | The Necessary Death of the Block Device Interface | 2013 | CIDR | 5.5269076e-05 |
| 7,247 | hStorage-DB: Heterogeneity-aware Data Management to Exploit the Full Capability of Hybrid Storage Systems | 2012 | VLDB | 4.790684e-05 |
| 1,817 | SSD Bufferpool Extensions for Database Systems | 2010 | VLDB | 0.00010435936 |
| 3,365 | Turbocharging DBMS Buffer Pool Using SSDs | 2011 | SIGMOD | 7.1728897e-05 |